{"id":179,"date":"2023-02-07T19:50:32","date_gmt":"2023-02-07T19:50:32","guid":{"rendered":"https:\/\/fipro.seolog.org\/?page_id=179"},"modified":"2023-03-07T08:35:23","modified_gmt":"2023-03-07T08:35:23","slug":"fire-pump-systems","status":"publish","type":"page","link":"https:\/\/www.fiprofire.com\/en\/fire-protection-systems\/fire-pump-systems\/","title":{"rendered":"Fire Pump Systems"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"179\" class=\"elementor elementor-179\">\n\t\t\t\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-bc78241 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"bc78241\" data-element_type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-761ec15d\" data-id=\"761ec15d\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b4e993f elementor-widget elementor-widget-heading\" data-id=\"b4e993f\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.16.0 - 09-10-2023 *\/\n.elementor-heading-title{padding:0;margin:0;line-height:1}.elementor-widget-heading .elementor-heading-title[class*=elementor-size-]>a{color:inherit;font-size:inherit;line-height:inherit}.elementor-widget-heading .elementor-heading-title.elementor-size-small{font-size:15px}.elementor-widget-heading .elementor-heading-title.elementor-size-medium{font-size:19px}.elementor-widget-heading .elementor-heading-title.elementor-size-large{font-size:29px}.elementor-widget-heading .elementor-heading-title.elementor-size-xl{font-size:39px}.elementor-widget-heading .elementor-heading-title.elementor-size-xxl{font-size:59px}<\/style><h1 class=\"elementor-heading-title elementor-size-default\">Fire Pump Systems<\/h1>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7cdd1fe elementor-icon-list--layout-inline elementor-align-center elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"7cdd1fe\" data-element_type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<link rel=\"stylesheet\" href=\"https:\/\/www.fiprofire.com\/en\/wp-content\/plugins\/elementor\/assets\/css\/widget-icon-list.min.css\">\t\t<ul class=\"elementor-icon-list-items elementor-inline-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Home Page<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-chevron-right\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Fire Protection Systems<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"fas fa-chevron-right\"><\/i>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\">Fire Pump Systems<\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9062d78 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9062d78\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-77a8edf\" data-id=\"77a8edf\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-728627f2 elementor-widget elementor-widget-heading\" data-id=\"728627f2\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fire Pump Systems<\/h2>\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2c832034 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2c832034\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-29dcd8f3\" data-id=\"29dcd8f3\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1ef8d9b elementor-widget elementor-widget-text-editor\" data-id=\"1ef8d9b\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.16.0 - 09-10-2023 *\/\n.elementor-widget-text-editor.elementor-drop-cap-view-stacked .elementor-drop-cap{background-color:#69727d;color:#fff}.elementor-widget-text-editor.elementor-drop-cap-view-framed .elementor-drop-cap{color:#69727d;border:3px solid;background-color:transparent}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap{margin-top:8px}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap-letter{width:1em;height:1em}.elementor-widget-text-editor .elementor-drop-cap{float:left;text-align:center;line-height:1;font-size:50px}.elementor-widget-text-editor .elementor-drop-cap-letter{display:inline-block}<\/style>\t\t\t\t<p>A fire pump is often part of the fire sprinkler system in large buildings. It is connected to the fire water tank and to the building&#8217;s sprinkler system at the discharge. The fire pump is activated when the pressure in the fire sprinkler system drops below a threshold. When one or more sprinkler heads are free active, water is discharged and the sprinkler system pressure drops significantly. The fire pump provides additional water pressure to the sprinkler system.<\/p><p>Fire pumps are also required where the municipal water system cannot maintain a high enough pressure to meet the pressure requirements of the fire sprinkler system. This usually occurs in systems that require high pressure to flush large volumes of water from sprinkler systems, such as multi-story buildings, large warehouses, large manufacturing plants. Fire pumps are needed if the fire protection water supply is from a ground-level water storage tank.<\/p><p>Fire Pumps can be operated with an electric motor or a diesel engine. A pump using an electric motor may require the installation of an emergency generator along with it.<\/p><p>The fire pump installation guidelines are the latest edition of the National Fire Protection Association&#8217;s (NFPA) NFPA 20 Standard for the Installation of Fixed Fire Pumps for Fire Protection.<\/p><p>During pump maintenance, operating pressures, water flow volume, amps and RPM readings should be recorded. It should be compared with the manufacturer&#8217;s specifications. Jockey Pumps should be checked. The performance of electrical or motor control units should be tested. All bearing assemblies should be lubricated, packing checked and minor adjustments made if necessary. All water supply systems should be visually inspected for any leaks.<\/p><p>Fipro engineers prepare a comprehensive report of the system status and keep your system ready for all fire hazards.<\/p>\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2f5fb526\" data-id=\"2f5fb526\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5415879 elementor-widget elementor-widget-image\" data-id=\"5415879\" data-element_type=\"widget\" data-settings=\"{&quot;_animation&quot;:&quot;none&quot;}\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t<style>\/*! elementor - v3.16.0 - 09-10-2023 *\/\n.elementor-widget-image{text-align:center}.elementor-widget-image a{display:inline-block}.elementor-widget-image a img[src$=\".svg\"]{width:48px}.elementor-widget-image img{vertical-align:middle;display:inline-block}<\/style>\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.fiprofire.com\/en\/wp-content\/uploads\/2023\/02\/fire-pump-2-1024x768.jpg\" class=\"attachment-large size-large wp-image-523\" alt=\"Fire Pump\" srcset=\"https:\/\/www.fiprofire.com\/en\/wp-content\/uploads\/2023\/02\/fire-pump-2-1024x768.jpg 1024w, https:\/\/www.fiprofire.com\/en\/wp-content\/uploads\/2023\/02\/fire-pump-2-300x225.jpg 300w, https:\/\/www.fiprofire.com\/en\/wp-content\/uploads\/2023\/02\/fire-pump-2-768x576.jpg 768w, https:\/\/www.fiprofire.com\/en\/wp-content\/uploads\/2023\/02\/fire-pump-2-1536x1152.jpg 1536w, https:\/\/www.fiprofire.com\/en\/wp-content\/uploads\/2023\/02\/fire-pump-2.jpg 2048w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Fire Pump Systems Home Page Fire Protection Systems Fire Pump Systems Fire Pump Systems A fire pump is often part of the fire sprinkler system in large buildings. It is connected to the fire water tank and to the building&#8217;s sprinkler system at the discharge. The fire pump is activated when the pressure in the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":97,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"footnotes":""},"class_list":["post-179","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/pages\/179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/comments?post=179"}],"version-history":[{"count":44,"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/pages\/179\/revisions"}],"predecessor-version":[{"id":1561,"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/pages\/179\/revisions\/1561"}],"up":[{"embeddable":true,"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/pages\/97"}],"wp:attachment":[{"href":"https:\/\/www.fiprofire.com\/en\/wp-json\/wp\/v2\/media?parent=179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}